MODELS: G 502 T/316SS, G 504 T/316SS
OPERATING INSTRUCTIONS, INSTALLATION & MAINTENANCE
MANUAL INCLUDING SPARE PARTS LIST
Mody Pumps Inc.
2166 Zeus Court
Bakersfield, CA 93308
Tel.: (661) 392-7600 FAX.: (661) 392-7601
http://www.modypump.com
Vista de pagina 0
1 2 3 4 5 6 ... 19 20

Indice de contenidos

Pagina 1 - Mody Pumps Inc

MODELS: G 502 T/316SS, G 504 T/316SS OPERATING INSTRUCTIONS, INSTALLATION & MAINTENANCE MANUAL INCLUDING SPARE PARTS LIST

Pagina 2 - Mody Pumps Inc.:

PARTS CATALOGUE. 1. COMPONENTS LIST : AS PER DRAWING NO. DW/200/201 (SHEET 1 & 2). DRAWINGS : 1. SECTIONAL ASSEMBLY (DW/200/0

Pagina 5

PUMP MODEL G502T/SS316 VER 1.0D.NO. PART NO. DESCRIPTION QTY1 065-014-79 CABLE 50'2 230-004-

Pagina 6

PUMP MODEL G502T/316SS VER 1.0D.NO. PART NO. DESCRIPTION QTY51 600-034-24 CAP FOR CIRCLIP 152 150

Pagina 9

PUMP MODEL G504T/316SS VER 1.0D.NO. PART NO. DESCRIPTION QTY1 065-014-79 CABLE 2 230-004-24 CABL

Pagina 10

PUMP MODEL G504T/316SS VER 1.0D.NO. PART NO. DESCRIPTION QTY51 600-034-24 CAP FOR CIRCLIP 152 15

Pagina 12

LLIIFFEE IISS PPRREECCIIOOUUSS -- TTHHIINNKK SSAAFFEETTYY 1. Most accidents can be avoided by using COMMON SENSE. 2. Please read the

Pagina 13

LIMITED WARRANTY We warrant to our immediate customer and to the ultimate consumer that products of our manufacture will be free of defects in ma

Pagina 14

INTRODUCTION THE “mody” MOTOR DRIVEN PORTABLE SUBMERSIBLE PUMPS HAVE BEEN DEVELOPED DUE TO A LONG FELT NEED OF HAVING A TRULY MAINTENA

Pagina 15

OVERALL DIMENSIONS AND WEIGHT. G 502/504T/316SS OVERALL HEIGHT 25.25”/640mm (APPROX.) MAX. DIAMETER

Pagina 16

MAINS VOLTAGE AT SITE HRC FUSE RECOMMENDED 220 VOLTS / 3 PHASE

Pagina 17

THE SEAL CHAMBER THE HEART OF THE MODY PUMP. TANDEM MECHANICAL, SILICON CARBIDE V/S SILICON CARBIDE SEAL FACES (LOWER SEAL) AND SILICON

Pagina 18

ELECTRICAL INFORMATION. MOTORS ARE DESIGNED TO OPERATE ON SINGLE VOLTAGE AND FREQUENCY. MAX. DEVIATION IN VOLTAGE ALLOWED IS + - 6 % A

Pagina 19

8. REMOVE THE FOUR NOS. DEEP SEATED CAP SCREWS (42) THAT HOLD THE LOWER BEARING BRACKET AGAINST THE INNER CASING. BY MEANS OF TWO NOS. S

Pagina 20 - LIMITED WARRANTY

5. FIT COMPLETE ROTOR ASSEMBLY IN STATOR HOUSING GUIDING UPPER BEARING IN TOP BRACKET BEARING SEAT. TIGHTEN FOUR CAP SCREWS (42). FIT UP